Specifications
|
|
No. of fibres to be spliced
|
Single
to single fibre. |
Fibre
cleaved length |
8-16mm
with 250mm outer coating diameter.
16mm (standard) or 8-16mm
(option) with outer coating diameter of more than 250mm up to 1000mm (1.0mm). |
Actual
average splice loss |
0.02dB
with SMF, 0.01dB with MMF, 0.04dB with DSF to ITU-T Reccommendations
G.652, G.651, G.653 respectively, when measured by the cut-back
method to relevant ITU-T and IEC standards. |
Splicing
time |
Typical
9 sec. |
Splicing
modes |
40
user programmable modes and up to 60 modes for reference (factory
predetermined setting). |
Splice
loss estimate |
Available |
Attenuation
splice function |
Intentional
high splice loss of 0.1dB to 15dB (0.1dB step) can be made for
an in-line fixed attenuator. |
Storage
of splice result |
The
last 2000 results to be stored in the internal memory. |
Fibre
display |
X
/ Y, or both X and Y simultanously. |
Magnification
of fibre |
295
for single X
or Y view, or 147 x for X and Y view. |
Viewing
method |
Two
MOSS
camera and 5.6 inch colour LCD monitor. |
Altitude,
humidity and Temperature compensation |
0
- 5000m above sea level, 0-95% RH and -10 - 50°C, respectively.
|
Mechanical
proof test |
2N
(standard), 4.4N (option). |
Tube
heater |
Built
in tube heater with 10 heating modes and up to 20 modes for
reference. |
Applicable
protection sleeve length
|
60mm,
40mm and a series of micro sleeves. |
No.
of splices with battery |
Typical 80 cycles with BTR-06(S) / Typical 160 cycles with BTR-06(L). |
Power
Supply |
Auto voltage selection from 100 – 240Va.c. or 10 to 15Vd.c. with ADC-11.
13.2Vd.c. with BTR-06(S/L). |
Wind
protection
|
Max.
wind velocity of 15m/s. |
Dimensions |
150W
x 150D x 150H (mm). |
Weight
|
2.3kg (2.8kg including AC adapter ADC-11). |